\documentclass[10pt]{article}
\usepackage[a4paper, top=3cm, left=2.5cm, right=2.5cm, bottom=2.5cm]{geometry}
\usepackage[usenames,dvipsnames]{color}
\usepackage{times}
\usepackage{enumitem}
\usepackage{hyperref}
\setlist{nolistsep}

\newcommand{\myincfig}[3]{
  \begin{figure}[htbp]
    \begin{center}
      \includegraphics[width=#2]{#1}
      \caption{\label{#1}#3}
    \end{center}
  \end{figure}
}

% \VignetteIndexEntry{PLLP image analysis}

\begin{document}
\SweaveOpts{concordance=TRUE}

\title{Lifetime-ratio analysis in the posterior lateral line primordium}
\author{Erika Don\`a, Joseph D. Barry, Guillaume Valentin, Charlotte Quirin,
\and Anton Khmelinskii, Andreas Kunze, Sevi Durdu, Lionel R. Newton,
\and Ana Fernandez-Minan, Wolfgang Huber, Michael Knop, Darren Gilmour}
\maketitle
\tableofcontents

\section{Introduction}

This document outlines the image analysis pipeline used to extract fluorescence
intensity ratios (referred to as `lifetime ratio') from image stacks of the
posterior lateral line primordium. All the code required to reproduce the
results presented in the main text is supplied. One example primordium dataset
was chosen for analysis in this vignette, but analyses of all other primordia
were performed in exactly the same way.

For this analysis the following confocal images acquired with identical imaging
settings were required:

\begin{enumerate}
 \item{Sample image: dual colour $z$-stack of a primordium.}
 \item{Sample background image: dual colour $z$-stack of a sample-free area in the dish.}
 \item{Ratio-normalisation image: dual colour image of purified mCherry-sfGFP
fusion protein, diluted in PBS.\label{imagec}}
 \item{Ratio-normalisation background image: dual colour image of PBS.\label{imaged}}
\end{enumerate}

Here green and red fluorescent channels are referred to as GFP and RFP. When
ratio comparison occurred among samples acquired with identical conditions,
\ref{imagec} and \ref{imaged} were not required.

\section{Loading required packages}

The analysis required the R packages \texttt{EBImage} and \texttt{parallel}. The
following R code may be used to obtain the packages.

<<label=installPackages, eval=FALSE, results=hide>>=
if (!requireNamespace("BiocManager", quietly=TRUE))
    install.packages("BiocManager")
BiocManager::install(c("EBImage", "parallel"))
@

The experiment data package \texttt{DonaPLLP2013} must also be loaded.

<<label=loadPackages, results=hide, eval=TRUE>>=
library("DonaPLLP2013")
@

\section{Loading image data}

Microscopy images of a posterior lateral line primordium (PLLP) were read into R
as follows. An example has been bundled with the loaded data package.

<<label=loadImages, results=hide, eval=TRUE, cache=TRUE>>=
xGFP <- readImage(system.file("extdata/cxcr4b_02C1.tif", package="DonaPLLP2013")) 
xRFP <- readImage(system.file("extdata/cxcr4b_02C2.tif", package="DonaPLLP2013")) 
@

A maximal projection of the $z$-stack was used to visualise the sample.

<<label=displayImages, eval=TRUE>>=
dim(xGFP)
xGFP.proj <- apply(xGFP, c(1, 2), max)
writeImage(normalize(xGFP.proj), "PLLPanalysis-displayImages.jpeg")
@

\myincfig{PLLPanalysis-displayImages.jpeg}{11cm}{Maximal $z$-projection of a
posterior lateral line primordium (green channel) before any background
subtraction or smoothing.}

\section{Defining parameters and setting units}

The voxel dimensions in this image were $0.1318$ x $0.1318$ x $1\ \mu m$,
information that was required later in our analysis pipeline. From this, the
dimensions of the field of view were calculated. We chose $5$ microns as the
characteristic length scale for our analysis (corresponding to half the
approximate diameter of primordium cells), and converted this to units of pixels
for later use.

<<label=setUnits, eval=TRUE>>=
Lpx <- c(x=0.1318, y=0.1318, z=1)
Lbox <- Lpx*dim(xGFP)  
Lbox
Leff <- round(5/Lpx["x"])           
Leff
@
\texttt{Lbox} was the length of the measurement box in microns, and
\texttt{Leff} the characteristic length in units of pixels (must be integer).

\section{Background subtraction}
\label{s:backgroundSubtraction}

The mean of the sample background image was subtracted for each fluorescence
channel.

<<label=backgroundSubtraction, results=hide, eval=TRUE>>=
xbckGFP <- readImage(system.file("extdata/bgC1.tif", package="DonaPLLP2013"))
xbckRFP <- readImage(system.file("extdata/bgC2.tif", package="DonaPLLP2013"))
xGFP <- xGFP-mean(xbckGFP, na.rm=TRUE)
xRFP <- xRFP-mean(xbckRFP, na.rm=TRUE)
@

\section{Smoothing}

Speckling due to Poisson noise was observed in the samples. For visualisation
purposes we decided to reduce the pixel noise by use of a low-pass filter. We
filtered each $z$-slice using a 2d Gaussian filter $5$ pixels wide as this was
approximately the width of the PSF in our imaging conditions. We required the
filter size to be an odd integer.

<<label=gaussianSmoothing, eval=TRUE, cache=TRUE>>=
Lpsf <- round(0.5/Lpx["x"])     
Lpsfodd <- ifelse(Lpsf%%2 == 0, Lpsf+1, Lpsf)
z <- makeBrush(size=Lpsfodd, shape="gaussian", sigma=Lpsfodd/2)
x2GFP <- filter2(xGFP, filter=z)
x2RFP <- filter2(xRFP, filter=z)
x2GFP.proj <- apply(x2GFP, c(1, 2), max)
writeImage(normalize(x2GFP.proj), "PLLPanalysis-gaussianSmoothing.jpeg")
@

\myincfig{PLLPanalysis-gaussianSmoothing.jpeg}{11cm}{Maximal $z$-projection of a
posterior lateral line primordium after background subtraction and smoothing.}

\section{Adaptive thresholding}

Adaptive thresholding was performed to obtain a mask of the membranes of the
primordium. A thresholding value of $0.01$ was used in our analysis, while the
size length of the thresholding box was set to the characteristic length of a
cell. Basic erosion and dilation operations were also performed to remove
remaining noise. As these operations modified the thickness of the membrane
mask, we used the same filter sizes for the analysis of all of our samples. For
this study, we verified that changing the mask thickness over one order of
magnitude had negligible effects on the ratio; see
Section~\ref{s:maskThickness}. 

We chose to define the mask using only the GFP channel for two reasons. First,
the GFP channel was considered as the reference channel in our analysis since it
was a better descriptor of protein abundance due to the fast maturation kinetics
of sfGFP. Second, sfGFP signal was more restricted to the plasma membrane than
the specific RFP used here, TagRFP, which showed greater perdurance in
intracellular vesicles. 

<<label=adaptiveThresholding, eval=TRUE>>= 
mk <- function(size) makeBrush(size, shape="disc")
mask <- thresh(x2GFP, w=Leff, h=Leff, offset=0.01)
mask <- erode(closing(mask, mk(Lpsfodd)), mk(Lpsfodd-2))
maskSlice <- mask[, , 20]
writeImage(maskSlice, "PLLPanalysis-maskSlice.jpeg")
maskDensity.proj <- apply(mask, c(1, 2), mean)
writeImage(normalize(maskDensity.proj), "PLLPanalysis-maskDensity.jpeg")
@

\myincfig{PLLPanalysis-maskSlice.jpeg}{11cm}{Binarized mask of primordium
membrane for $z$-slice 20. White pixels indicated segmented membrane.}

\myincfig{PLLPanalysis-maskDensity.jpeg}{11cm}{The mean projection in the
$z$-direction of the membrane mask gave an impression of membrane density, and
was useful for visualisation purposes.}

\section{Sample alignment along axis of migration}

To measure the RFP/GFP intensity ratio along the principal direction of
migration (elongation axis) of the primordium we aligned the samples along this
direction. It was convenient to first obtain a 2d mask\footnote{For condition
mem-tFT a 3d mask was required due to the persistence of signal in the muscle
layer underneath the primordium, which is to be expected from the slow
degradation rate of the membrane-tethered protein.} of the primordium in the
$xy$ plane. We did this by filling holes in the image using the
\texttt{fillHull} function from the package \texttt{EBImage}, followed by a
maximal intensity projection of the $z$-stack. The segmentation was improved
upon by using additional opening and closing operations. All objects except the
largest were subsequently removed as the primordium mask was the object with the
largest area in the field of view. Finally, \texttt{fillHull} was used again to
fill any remaining holes.

<<label=obtainOrganMask, eval=TRUE>>=
organ.mask <- apply(fillHull(mask), c(1, 2), max) 
organ.mask <- opening(closing(organ.mask, mk(Leff/2)), mk(Leff/2))
organ.labels <- bwlabel(organ.mask)
I <- which(table(organ.labels)[-1] < max(table(organ.labels)[-1])) 
organ.mask <- rmObjects(organ.labels, I)
organ.mask[organ.mask > 0] <- 1
organ.mask <- fillHull(organ.mask)
writeImage(organ.mask, "PLLPanalysis-organMask.jpeg")
@

\myincfig{PLLPanalysis-organMask.jpeg}{11cm}{An $xy$-segmentation of the whole
organ is obtained to determine the axis of migration and to ascertain the
location of the leading edge.}

An example of the resulting segmentation can be seen in
Fig.~\ref{PLLPanalysis-organMask.jpeg}. From the $xy$ mask of the primordium, we
computed the major axis of inertia using principal component analysis. The angle
of this principal axis with respect to horizontal was stored in degrees.

<<label=principalComponentAnalysis, eval=TRUE>>=
organ.coord <- as.data.frame(which(organ.mask == 1, arr.ind=TRUE),
                             stringsAsFactors=FALSE) 
colnames(organ.coord) <- c("x", "y")
organ.coord$x <- (organ.coord$x-1)*Lpx["x"]
organ.coord$y <- -(organ.coord$y-1)*Lpx["y"]
organ.pca <- prcomp(organ.coord)
pc1 <- organ.pca$rotation[, 1]
pc1.theta <- atan(pc1["y"]/pc1["x"])*(180/pi)
pc1.theta
@

All images were rotated so that they lay along the axis of migration. Extra
parameters were passed to the \texttt{rotate} function to ensure that the
rotated images fit fully into the new field of view.
 
<<label=rotateImages, eval=TRUE>>=
xGFP <- rotate(xGFP, angle=pc1.theta)
xRFP <- rotate(xRFP, angle=pc1.theta)
x2GFP <- rotate(x2GFP, angle=pc1.theta)
x2RFP <- rotate(x2RFP, angle=pc1.theta)
mask <- rotate(mask, angle=pc1.theta)
organ.mask <- rotate(organ.mask, angle=pc1.theta)
@

\section{Excluding signal outside of primordium}

By inspection of the membrane mask, we observed foreground pixels that lay
outside of the primordium. As we were rather interested in cxcr4b turnover
within the primordium, we excluded pixels that lay outside of the $xy$ tissue
mask of Fig.~\ref{PLLPanalysis-organMask.jpeg}.

<<label=excludeExteriorPixels, eval=TRUE>>=
organ.mask.rep <- replicate(dim(xGFP)[3], organ.mask)
I1 <- which(organ.mask.rep == 1)
I2 <- which(mask == 1)
I <- intersect(I1, I2)
mask <- array(0, dim=dim(organ.mask.rep))
mask[I] <- 1
@

\section{Cropping images for computational efficiency}

For the sake of computational efficiency in the subsequent running median
calculation, we cropped the images so that the field of view only contained the
segmented primordium.

<<label=cropImages, eval=TRUE>>=
I <- which(organ.mask.rep == 1, arr.ind=TRUE)
intRange <- function(x) {rg=range(x); seq(rg[1], rg[2], by=1)}
x.range <- intRange(I[, 1])
y.range <- intRange(I[, 2])
xGFP <- xGFP[x.range, y.range, ]
xRFP <- xRFP[x.range, y.range, ]
x2GFP <- x2GFP[x.range, y.range, ]
x2RFP <- x2RFP[x.range, y.range, ]
mask <- mask[x.range, y.range, ]
organ.mask <- organ.mask[x.range, y.range]
writeImage(organ.mask, "PLLPanalysis-cropImages.jpeg")
@

The coordinates of the field of view were also recalculated to account for the
cropping.

<<label=cropCoordinates, eval=TRUE>>=
Lbox <- Lpx*dim(xGFP)
Lbox
@

\myincfig{PLLPanalysis-cropImages.jpeg}{9cm}{The organ mask was rotated so that
it is aligned with the axis of migration, and cropped so that only the
primordium was in the field of view. Compare with the pre-rotated and uncropped
Fig.~\ref{PLLPanalysis-organMask.jpeg}.}

\section{Running median}
\label{s:runningMedian}

Before measuring the RFP/GFP fluorescence intensity ratio across the principal
axis of our specimen, a running median on the raw data within the mask was
computed to reduce the effects of pixel noise and chromatic aberration. Taking
the median also reduced the contribution of RFP-rich vesicles to the RFP signal,
which were sometimes observed close to the membrane, and therefore could fall
within the membrane mask. This approach had merit provided that the volume of
the box we were taking the median in was sufficiently larger than the volume of
the vesicle that was lying on the membrane. Here we defined the size length of
the cube for the running median to be $10$ microns and the isotropic grid points
on which to center this cube were spaced by $5$ microns.

The following additional functions were required. \texttt{getCoordinates}
receives a continuous range in microns and returns the corresponding discrete
pixel coordinates. \texttt{getCubeIntensity} calculates the running median at
specified locations. \texttt{runningMedian} is a wrapper function that calls
\texttt{getCoordinates} and \texttt{getCubeIntensity} at each point on a spatial
grid.

As the running median algorithm was straightforward to parallelize,
\texttt{runningMedian} made use of the \texttt{mclapply} function from the
\texttt{parallel} package to distribute the computation across available cores.

<<label=runningMedianFunctions, eval=TRUE>>=
getCoordinates <-
function(s, xrange, yrange, zrange) {
    Ix=which(s$x >= min(xrange) & s$x <= max(xrange))
    Iy=which(s$y >= min(yrange) & s$y <= max(yrange))
    Iz=which(s$z >= min(zrange) & s$z <= max(zrange))
    return(list(x=Ix, y=Iy, z=Iz))
}

getCubeIntensity <-
function(x0, x, y, z, spatial, Lcube) {
    crd <- getCoordinates(spatial,
                          xrange=c(x-Lcube/2, x+Lcube/2),
                          yrange=c(y-Lcube/2, y+Lcube/2),
                          zrange=c(z-Lcube/2, z+Lcube/2))
    cube.median <- median(imageData(x0)[crd$x, crd$y, crd$z], na.rm=TRUE)
    return(list(median=cube.median))
}

runningMedian <-
function(x, grid.x, grid.y, grid.z, Lx, Ly, Lz, nCores=2, Lcube) {
    grid <- as.list(data.frame(t(expand.grid(grid.x, grid.y, grid.z))))
    spatial <- list(x=(1:dim(x)[1]-1)*Lx, 
                    y=(1:dim(x)[2]-1)*Ly,
                    z=(1:dim(x)[3]-1)*Lz)
    chooseCores <- function(numCoresWanted) {
        if(.Platform$OS.type == "windows") return(1)
        return(numCoresWanted)
    }
    dataIntensities <-
        mclapply(grid, function(s) getCubeIntensity(x0=x, x=s[1], y=s[2], z=s[3],
                                                    spatial=spatial, Lcube=Lcube), 
                 mc.cores=chooseCores(nCores), 
                 mc.preschedule=FALSE)
    dataIntensities=unlist(dataIntensities)
    result.median=array(dataIntensities,
                        dim=c(length(grid.x), length(grid.y), length(grid.z)))
    return(result.median)
}
@

The spatial grid was defined in $x$, $y$ and $z$ coordinates of the specimen,
the dimensions of the cube in which the running median was calculated, and the
spacing between points on our grid.

<<label=runningMedianGrid, eval=TRUE>>=
Ljump <- 5
Lcube <- 10
grid.x <- seq(from=0, to=Lbox["x"], by=Ljump)
grid.y <- seq(from=0, to=Lbox["y"], by=Ljump)
grid.z <- seq(from=0, to=Lbox["z"], by=Ljump)
@

Any pixel values in the GFP and RFP images that did not lie on the membrane mask
were set to $NA$ so that they did not contribute to the calculation.

<<label=runningMedian, eval=TRUE, cache=TRUE>>=
I <- which(mask == 0)
xGFP.maskOnly <- xGFP
xRFP.maskOnly <- xRFP
xGFP.maskOnly[I] <- NA
xRFP.maskOnly[I] <- NA
resultGFP <- runningMedian(x=xGFP.maskOnly, 
                           grid.x=grid.x, grid.y=grid.y, grid.z=grid.z, 
                           Lx=Lpx["x"], Ly=Lpx["y"], Lz=Lpx["z"], 
                           nCores=4, Lcube=Lcube)
resultRFP <- runningMedian(x=xRFP.maskOnly, 
                           grid.x=grid.x, grid.y=grid.y, grid.z=grid.z, 
                           Lx=Lpx["x"], Ly=Lpx["y"], Lz=Lpx["z"], 
                           nCores=4, Lcube=Lcube)
@

<<label=plotFluorescenceChannels, eval=TRUE, fig=TRUE, include=FALSE>>=
GFP.profile=apply(resultGFP, 1, median, na.rm=TRUE)
RFP.profile=apply(resultRFP, 1, median, na.rm=TRUE)
plot(-grid.x, rev(GFP.profile), 
     xlab="Distance from leading edge (microns)", 
     ylab="Fluorescence intensity (a.u.)", 
     type="b", 
     axes="F", 
     pch=1, 
     ylim=c(0, range(GFP.profile, RFP.profile, na.rm=TRUE)[2]), 
     col="darkgreen")
points(-grid.x, rev(RFP.profile), type="b", pch=2, col="red")
axis.at.x <- seq(-200 ,0 , by=25)
axis(1, at=axis.at.x, labels=-axis.at.x)
axis(2)
legend("topright", legend=c("GFP", "RFP"), pch=1:2, col=c("darkgreen", "red"))
@

\myincfig{PLLPanalysis-plotFluorescenceChannels.pdf}{9cm}{Median RFP and GFP
fluorescence intensities across the primordium.}

We visualised signal in the direction of migration by taking an additional
running median along this axis
(Fig.~\ref{PLLPanalysis-plotFluorescenceChannels.pdf}).

<<label=plotRatio, eval=TRUE, fig=TRUE, include=FALSE>>=
resultRatio <- resultRFP/resultGFP
ratio.profile <- apply(resultRatio, 1, median, na.rm=TRUE)
plot(-grid.x, rev(ratio.profile), 
     xlab="Distance from leading edge (microns)", 
     ylab="RFP/GFP fluorescence intensity ratio (-)", 
     type="b", 
     axes="F")
axis.at.x <- seq(-200, 0, by=25)
axis(1, at=axis.at.x, labels=-axis.at.x)
axis(2)
@

\myincfig{PLLPanalysis-plotRatio.pdf}{9cm}{The RFP/GFP intensity ratio increased
towards the back of the primordium, indicating an increased stability, or longer
lifetime, of cxcr4b receptors.}

To obtain a localised readout for cxcr4b stability, we took the ratio of the RFP
to GFP signal; see Fig.~\ref{PLLPanalysis-plotRatio.pdf}. For graph
interpretation note that the higher the RFP/GFP ratio, the higher the age of the
protein.


\section{Correcting for day-to-day variability}

From day-to-day, there can be variability in signal due to intentional changes
in laser power by the experimenter, undesirable daily fluctuations in the chosen
laser power, as well as other unknown factors. Here we used a solution of
purified sfGFP-mCherry fusion protein as a daily control. In
Section~\ref{s:theorySolutionCorrection} we explain why it is appropriate to
normalise the TagRFP/sfGFP ratio of each imaged primordium by the mCherry/sfGFP
fluorescence intensity of the control.

Before calculating the mCherry/sfGFP ratio from the ratio-normalisation image,
we performed background subtraction.

<<label=solutionBackgroundSubtraction, results=hide, eval=TRUE>>=
solGFP <- readImage(system.file("extdata/1_100_mCherryC1.tif",
                    package="DonaPLLP2013"))
solGFPbck <- readImage(system.file("extdata/PBSC1.tif", package="DonaPLLP2013"))
solRFP <- readImage(system.file("extdata/1_100_mCherryC2.tif",
                    package="DonaPLLP2013"))
solRFPbck <- readImage(system.file("extdata/PBSC2.tif", package="DonaPLLP2013"))
solRFP <- solRFP-mean(solRFPbck)
solGFP <- solGFP-mean(solGFPbck)
@

We then formed the average mCherry/sfGFP fluorescence intensity ratio of the
solution and divided the sample ratio by this number.

<<label=correctSampleRatioByControlRatio, eval=TRUE>>=
solRatio <- mean(solRFP)/mean(solGFP)
resultRatioCorrected <- resultRatio/solRatio
@

\section{Tissue-scale ratio measurement}

To obtain an estimate of whole-primordium receptor stability, the median ratio
was computed across the sample. In each case this was done on the
solution-corrected ratios.

<<label=wholeSampleRatio>>=
print(median(resultRatioCorrected, na.rm=TRUE))
@


\section{Theoretical explanation for ratio correction}
\label{s:theorySolutionCorrection}

For a given fluorophore, fluorescence intensity is proportional to the number of
mature fluorescent proteins present. The proportionality factor $f$ is constant
for a particular fluorophore and is related to its brightness. $h$ is the laser
power used on a given day, in suitable units. We also consider additive noise
$\xi$ (normally referred to as background), and multiplicative noise $e^\epsilon
\approx 1$ with $\epsilon \sim N(0,\sigma^2)$, which encompasses daily laser
power fluctuations or other unknown effects. We denote the fluorescence
intensity measurement $I$ per volume per unit time for a given fluorescence
channel as

\begin{equation}
 I=e^\epsilon f h X + \xi\ .
\end{equation}

In Section~\ref{s:backgroundSubtraction} background subtraction was performed on
each channel to reduce the additive noise. We assume that the resulting
corrected image $\hat{I}$ had negligible additive noise, and therefore ignore
the $\xi$ term. Denoting the TagRFP/sfGFP ratio calculated in
Section~\ref{s:runningMedian} as $R$, we have

\begin{equation}
 R=\frac{\hat{I_r}}{\hat{I_g}}=\frac{e^{\epsilon_{\mbox{\tiny 561}}}
f_{\mbox{\tiny TagRFP}} h_{\mbox{\tiny 561}}  X_r}{e^{\epsilon_{\mbox{\tiny
488}}} f_{\mbox{\tiny sfGFP}} h_{\mbox{\tiny 488}} X_g}
\label{eq:ratio}
\end{equation}
The subscripts $r$ and $g$ refer to the RFP and GFP channels, respectively.
$561$ and $488$ denote the excitation wavelengths in nanometers of the RFP and
GFP channels, respectively.

Background subtraction was also performed for the solution of mCherry-sfGFP
tandem fluorescent timer, resulting in the following expression for the ratio:

\begin{equation}
 R^s=\frac{\hat{I_r^s}}{\hat{I_g^s}}=\frac{e^{\epsilon_{\mbox{\tiny 561}}}
f_{\mbox{\tiny mCherry}} h_{\mbox{\tiny 561}}  X_r^s}{e^{\epsilon_{\mbox{\tiny
488}}} f_{\mbox{\tiny sfGFP}} h_{\mbox{\tiny 488}} X_g^s}
\label{eq:ratiosolution}
\end{equation}
The superscript $s$ here indicates terms that are representative of the
mCherry-sfGFP solution. $f_{\mbox{\tiny mCherry}}$ is the proportionality factor
of mCherry. For an ideal solution of fully mature fluorophores, where no
misfolding has occurred, $X_r^s/X_g^s=1$ but in reality, this number will not be
exactly equal to $1$. Instead we assume it has a constant purity,
$P=X_r^s/X_g^s$, as the solution was always prepared from the same batch, and
had a large number of molecules. Therefore, by dividing eq.~\ref{eq:ratio} by
eq.~\ref{eq:ratiosolution}, the multiplicative noise and other linear terms
cancel out, resulting in

\begin{equation}
 \hat{R}=\frac{R}{R^s}=c \frac{X_r}{X_g}
\label{eq:normalisedratio}
\end{equation}
, where we have defined a new constant $c=f_{\mbox{\tiny TagRFP}} / (P
f_{\mbox{\tiny mCherry}})$. $\hat{R}$ denotes the control-normalised ratio.

All image data presented in the main text was corrected for additive and
multiplicative noise, as described in this section. The normalisation by the
control solution of mCherry-sfGFP eliminated any time-dependent noise factors
(on the scale of days) and thus allowed us to group measurements of the same
condition taken on different days, and to directly compare ratio profiles across
different genetic conditions.

We note that as long as the laser powers remain constant during a given
microscope session for the imaging of both sample and control, in principle one
does not need to explicitly know their values, as they cancel out during the
control normalisation step. Although not incorporated into the above equations,
the same is true for other linear terms such as exposure time. Nevertheless,
where possible, it is good practice to record these values for future reference.

\section{The effect of mask thickness on the ratio}
\label{s:maskThickness}

Earlier we remarked that changes in the membrane mask thickness due to opening
and closing morphological operations, did not substantively change the RFP/GFP
fluorescence intensity ratio. We demonstrated this on tissue-scale measurements
by progressively thickening, and then progressively thinning the membrane mask.
After each change in thickness, the tissue-scale RFP/GFP ratio was measured for
pixels lying on the mask.

<<label=varyMembraneThickness, eval=TRUE, fig=TRUE, include=FALSE>>=
membraneRatio <- array(dim=5)
I <- which(mask == 1)
membraneRatio[3] <- median(xRFP[I])/median(xGFP[I])

calcRatioOnModifiedMembrane <- function(xGFP, xRFP, mask, morph=erode, steps=1) {
 for (i in seq_len(steps)) mask <- morph(mask, mk(2))
 I <- which(mask == 1)
 return(median(xRFP[I])/median(xGFP[I]))
}

membraneRatio[1] <- calcRatioOnModifiedMembrane(xGFP, xRFP, mask, erode, 2)
membraneRatio[2] <- calcRatioOnModifiedMembrane(xGFP, xRFP, mask, erode, 1)
membraneRatio[4] <- calcRatioOnModifiedMembrane(xGFP, xRFP, mask, dilate, 1)
membraneRatio[5] <- calcRatioOnModifiedMembrane(xGFP, xRFP, mask, dilate, 2)
plot(1:5, membraneRatio, xlab="Mask ID", 
     ylab="RFP/GFP fluorescence intensity ratio (-)", 
     ylim=c(0, max(membraneRatio)))
@

\myincfig{PLLPanalysis-varyMembraneThickness.pdf}{9cm}{Whole-primordium median
RFP/GFP fluorescence intensity ratios for membrane masks of varying thickness.
The mask thickness increases from left to right.}

Fig. \ref{PLLPanalysis-varyMembraneThickness.pdf} showed that as the thickness
of the membrane is varied over a range of the order of a micron, the RFP/GFP
ratio changed by only approximately 10\%. Any additional thickening or thinning
of the mask outside of this range resulted in an inaccurate segmentation, and so
these cases were not considered. 

\end{document}